Landfill and Sewage Treatment Plant PFAS Monitoring Chemical Control Order
A new Landfill and Sewage Treatment Plant PFAS Monitoring Chemical Control Order (CCO) has been introduced.
The CCO (PDF 262KB) requires licensed landfills and sewage treatment plants (STPs) to monitor for per‑ and polyfluoroalkyl substances (PFAS) and report results to the EPA.
The CCO commenced on 1 October 2026.
Introduction of PFAS Monitoring CCO
PFAS are chemicals that persist in the environment. Landfills and sewage treatment plants generally receive PFAS from other sources, rather than creating them. These facilities are considered secondary receivers of PFAS.
Currently, monitoring requirements for PFAS differ across sites. This makes it difficult to compare data and understand PFAS pathways across NSW.
The EPA has introduced this CCO to:
- establish consistent, science‑based PFAS monitoring requirements
- improve understanding of PFAS concentrations and pathways from licensed landfills and STPs
- collect data to inform future regulatory decisions
- support protection of the environment.
The requirements align with the PFAS National Environmental Management Plan (PFAS NEMP 3.0).
Who the CCO applies to
The CCO applies to:
- licensed landfills in NSW
- licensed sewage treatment plants in NSW
If you hold an environment protection licence for one of these facilities, you are required to comply with the CCO, which commenced on 1 October 2026.
What licence holders must do
Under the CCO, relevant licence holders must:
- monitor for PFAS at specified locations
- use approved sampling and analytical methods
- monitor on a quarterly basis
- report results to the EPA in the required format and timeframes.
PFAS (per- and polyfluoroalkyl substances) are a group of synthetic chemicals used in a wide range of industrial and consumer products. They do not easily break down and can persist in the environment for a long time. PFAS can accumulate in soil, water, and living organisms, creating potential exposure pathways for humans and wildlife.
A CCO is a regulatory tool under the Protection of the Environment Operations Act 1997 that allows the EPA to control the use, handling, and disposal of certain chemicals. It can also require monitoring or phase-out of specific substances.
The CCO aims to establish consistent monitoring requirements for PFAS at licensed sewage treatment plants and landfills. This monitoring data will help us assess the PFAS concentrations at these sites and inform if further investigations and action are needed.
All licensees for landfills and sewage treatment plants who hold an Environment Protection Licence (EPL) must comply with the CCO. This includes closed sites with active licences.
The PFAS NEMP has identified that landfill leachate and effluent from sewage treatment plants are secondary sources of PFAS in the environment. The PFAS NEMP contains guideline values that act as a trigger to undertake further investigations if those values are exceeded. Monitoring helps identify where PFAS is entering the environment and in what concentrations. This data is essential for assessing environmental risks and determining whether further regulatory action is needed.
Table 1 in the CCO lists the chemicals as:
- Perfluorooctanoic acid (PFOA)
- Perfluorooctanesulfonic acid (PFOS)
- Perfluorohexanesulfonic acid (PFHxS) and
- Perfluorobutanesulfonic acid (PFBS).
For landfills, monitoring of leachate must occur once per year, and for downgradient groundwater, four times per year on a quarterly basis.
If a landfill does not have an appropriate groundwater monitoring location, then a surface water monitoring location can be used.
For sewage treatment plants, monitoring of treated effluent must be conducted four times per year on a quarterly basis.
The EPA does not expect new groundwater monitoring locations to be established.
Licensees are not required to install new groundwater monitoring locations to comply with the Landfill and STP PFAS Monitoring CCO.
A groundwater sample must be collected from a groundwater monitoring location specified in the licence, that is downgradient of each landfill cell.
Licensees should use available site information, such as hydrogeological assessments, groundwater contour maps, site plans, landfill design drawings, investigation reports, groundwater monitoring programs and landfill management plans, to identify which licenced groundwater monitoring locations are downgradient of landfill cells. The licence does not need to explicitly identify a monitoring location as being downgradient for monitoring to be required.
Where multiple landfill cells are monitored by the same downgradient groundwater monitoring location, a single monitoring location may be sufficient. However, where a single monitoring location is not downgradient of all landfill cells, additional licensed groundwater monitoring locations may need to be sampled to ensure potential PFAS migration from each landfill cell is appropriately monitored.
Where multiple licensed groundwater monitoring locations are downgradient of a landfill cell, the licensee should select the location that is most likely to detect potential PFAS migration from that cell.
Licensees are not required to collect both groundwater and surface water samples for the same landfill cell under the Landfill and STP PFAS Monitoring CCO. Surface water monitoring is only required where a licenced downgradient groundwater monitoring location is not available.
If there are no licenced groundwater monitoring locations downgradient of a landfill cell, the licensee must collect a surface water sample from a licensed surface water monitoring location downstream of that landfill cell.
Where multiple licensed surface water monitoring locations are available, the licensee should select the location that is most appropriate to detect potential PFAS migration from the landfill cell to the receiving environment.
If there are no licensed groundwater monitoring locations downgradient of a landfill cell and no licensed surface water monitoring locations downstream of that landfill cell, the licensee should identify a suitable alternative surface water monitoring location that is most likely to detect potential PFAS migration from the landfill cell to the receiving environment.
The licensee should contact the EPA to discuss the proposed monitoring location before sampling is undertaken. In selecting a suitable location, licensees should use available site information, such as hydrogeological assessments, groundwater contour maps, site plans, landfill design drawings, investigation reports, groundwater monitoring programs and landfill management plans, to identify a location that is representative of potential PFAS migration pathways.
If the licensee is uncertain about an appropriate sampling location, they should contact the EPA for advice.
An exception report can be submitted in lieu of monitoring data in circumstances where a licensee is unable to carry out the monitoring required under the Landfill and STP PFAS Monitoring CCO (for example, where there is no surface water or groundwater at a monitoring point at the time scheduled for sampling).
Exception reports will be considered on a case-by-case basis and the EPA expects exception reports to include sufficient justification for monitoring not being undertaken as required by the Landfill and STP PFAS Monitoring CCO. The EPA may request further information and/or evidence in association with an exception report if deemed necessary.
It is noted that, if the EPA accepts an exception report, this is only applicable to the relevant reporting period. Further exception reports will need to be submitted in accordance with the reporting requirements of the Landfill and STP PFAS Monitoring CCO.
There is no prescribed format for an exception report. When submitting monitoring results through eConnect, licensees can indicate that an exception report is being provided and select the most relevant exception category, such as:
- extreme weather event preventing sampling
- no discharge for more than three months
- other.
While the exception category selected may be generic, the exception report should clearly describe the site-specific circumstances that prevent sampling from being undertaken.
For example, where a downgradient groundwater monitoring location is dry, the exception report should document that the monitoring location was inspected in accordance with the required monitoring schedule and that the absence of water was confirmed through site observations. Supporting information, such as photographs, field notes and sampling records should be included where available.
Exception reports do not need to be complex; however, they should provide sufficient information and evidence to explain why a sample could not be collected or analysed.
The Landfill and STP PFAS Monitoring CCO is a separate regulatory instrument made under sections 296I and 296J of the Protection of the Environment Operations Act 1997 and introduces specific PFAS monitoring and reporting requirements. Compliance with the Landfill and STP PFAS Monitoring CCO is assessed independently of licence requirements.
Licensees are not required to publish data collected under the Landfill and STP PFAS Monitoring CCO.
Existing Environment Protection Licence (EPL) conditions
If a licensee already conducts monitoring for PFAS that meets the requirements of the CCO, then the licensee can submit that data to the EPA for consideration.
Licensees are responsible for ensuring that PFAS samples are collected and analysed in accordance with the requirements of the Landfill and STP PFAS Monitoring CCO.
Licensees may undertake sampling themselves or engage a suitably qualified environmental consultant. It is the responsibility of the licensee to ensure that sampling personnel are competent and that appropriate sampling procedures, equipment and containers are used to minimise the risk of contamination and ensure reliable results.
Samples must be analysed by a laboratory that holds appropriate accreditation for PFAS analysis using the analytical methods specified in the Landfill and STP PFAS Monitoring CCO.
For more information about PFAS sampling, read the national guidance on PFAS sampling and analysis is set out in Chapter 18 of the PFAS National Environmental Management Plan version 3.1.
The analysis must be performed in accordance with the methods described in the Approved methods for the sampling and analysis of water pollutants in NSW, using a method that is appropriate for the analysis of PFAS in Aqueous Samples by LC-MS/MS, based on USEPA 1633A.
The monitoring data will help us assess the PFAS concentrations at these sites and inform if further investigations and action are needed. We will collate and analyse the monitoring data to identify trends and inform future regulatory decision‑making.
PFAS monitoring data collected under the Landfill and STP PFAS Monitoring CCO is intended to improve understanding of PFAS occurrence, movement and potential environmental risks associated with sewage treatment plants and landfills. PFAS NEMP guideline values are investigation triggers rather than regulatory limits.
Where elevated PFAS concentrations are identified, the EPA may use this information to better understand potential contamination pathways and associated environmental risks. The findings may also help inform future investigations, monitoring programs or regulatory decisions, where appropriate.
The PFAS monitoring data collected under the Landfill and STP PFAS Monitoring CCO is intended to improve understanding of PFAS occurrence, movement and potential environmental risks associated with sewage treatment plants and landfills.
If PFAS is identified in landfill leachate, the EPA will consider a range of factors, including PFAS concentrations in groundwater and/or surface water samples, the potential for releases to the environment, PFAS exposure pathways, and the associated environmental risks. These considerations may inform whether changes to leachate management practices are warranted.
Where necessary, the EPA will work with licensees and other government agencies to identify and implement appropriate leachate management measures to reduce environmental risks.
More information
For more information or enquiries about PFAS, email the Environment Line at [email protected]